RECOMMENDED FOR: Hydraulic control pipeline for BOP control equipment.
TEMPERATURE: -20℃~+121℃.
STRUCTURE: A structure of lining, reinforcement, flame-retardant and thermal insulaiton layer
and protection cover with coupling patent design, patent No.: ZL00214874.9.
PROPERTY: Under temperature of 1093℃(2000℉), the product can perform well for more
than 5 minutes under working pressure. The product is successfully approved
as the National Torch Plan project in 2002 by State Science and Technology
Committee considering its advanced technology and strong practicability.
STANDARD: API Spec 16D
MAIN PARAMETER:
I.D. in. (mm) |
W.P. psi |
T.P. psi |
Min bending radius mm |
3/4 19 | 1500 | 3000 | 240 |
3/4 19 | 3000 | 4500 | 240 |
3/4 19 | 5000 | 7500 | 280 |
3/4 19 | 6500 | 9750 | 280 |
1 25 | 1500 | 3000 | 300 |
1 25 | 3000 | 4500 | 300 |
1 25 | 5000 | 7500 | 360 |
1 25 | 6500 | 9750 | 360 |